ITEM DESCRIPTION
This control panel is suitable with all Autoterm air heaters 12V and 24V
The following are located on the front of the panel:
Ventilation mode on/off button
Heater on/off button
Potentiometer dial
There are 3 operating modes for this controller:
“Power” (if the interior sensor is not connected)
-designed for quickest possible heating of the space
-the heater operates continuously at a set power
"Temperature” (if the interior sensor is connected)
-designed to heat the space to the required temperature
-heat output decreases as the difference between the desired temperature and the temperature in the space decreases
“Ventilation”
-designed for air circulation in the space
“Ventilation during heating” function (if the interior sensor is connected)
-designed to maintain the required temperature in the space
-after the required temperature is reached, the space heating is stopped and space air circulation is performed
-controls the space temperature; if the temperature drops below the set point, the heater will start in heating mode
The LED at the top of the controller indicates the heater status:
-yellow light - heating mode
-fast blinking yellow – during purging
-slowly blinking red - in case of malfunction
-off - heater is not operational
The LED at the bottom of the controller indicates the ventilation mode status:
-green light - interior sensor is not connected and heater operates in ventilation mode
-green blink - ventilation mode off
-yellow light - the interior sensor is connected and the heater operates in heating mode with ventilation function
-off - heater is not operational, with ventilation mode off
--------------------
PACKAGE INCLUDES -
- Autoterm basic heater control panel
--------------------
ADDITIONAL NOTES -
* Please note, that AUTOTERM air heaters with production date 16.11.2016 or older does not support Ventilation mode. You can check your air heaters AUTOTERM production date on the warranty card
** Please note, that all AUTOTERM air heaters need external temperature sensor (assy.1458), so that the "Power mode" and "Ventilation during heating” function would work